Tel: 905.335.5960 | Fax: 905.335.5994 | sales@macromotion.ca
Fluid Power Experts Specializing in Hydraulics, Pneumatics and Hose & Fittings in Ontario, Canada
NUMATICS ISO SERIES PNEUMATIC VALVES
Numatics ISO series valves are high speed, heavy duty valves, designed for general service on all types of automation. Valves comply with ISO standard 5599/1 for valve unit to base interchangeability as well as 5599/2 and 15407-2. Direct solenoid, solenoid pilot and air pilot actuated models available. They are true multi-purpose valves and employ the patented Numatics spool and sleeve assembly.
ISO 5599/1 Valves
Standard Specifications:
-
Cv:
-
5599/1-1: 1.2
-
5599/1-2: 1.7
-
5599/1-3: 4.4
-
-
Port Sizes:
-
5599/1-1: 1/4 & 3/8 NPTF
-
5599/1-2: 1/4 & 3/8 NPTF
-
5599/1-3: 1/2 NPTF
-
-
5 ported, 4-way, 2 and 3 position, spool & sleeve
-
Operating Pressure Range:
-
Direct Solenoid: 28" Hg. Vacuum to 232 PSIG / Vacuum to 16 bar
-
Solenoid Pilot:
-
Internal Pilot: 14.5 to 232 PSIG / 1 to 16 bar
-
External Pilot:
-
Main Valve: 28" Hg. Vacuum to 232 PSIG / Vacuum to 16 bar
-
Pilot Supply: 14.5 to 232 PSIG / 1 to 16 bar
-
-
-
Air Pilot:
-
Main Valve: 28" Hg. Vacuum to 232 PSIG / Vacuum to 16 bar
-
Pilot Supply: 14.5 to 232 PSIG / 1 to 16 bar
-
-
-
Temperature Range (Ambient): -10°F to +115°F / -23°C to +46°C
Features:
-
Direct solenoid, solenoid air pilot, and air pilot actuated
-
Conforms to ISO standards 5599/1
-
High speed, heavy duty design
-
AC or DC
-
NEMA 4/IP65
5599/1
ISO 5599/2 & 15407-2 Valves
Standard Specifications:
-
Cv:
-
5599/2-1: 1.3
-
5599/2-2: 2.9
-
5599/2-3: 5.3
-
15407-2, 18mm: 0.56
-
15407-2, 26mm: 1.2
-
-
Port Sizes:
-
5599/2-1: 1/4 & 3/8 NPTF
-
5599/2-2: 3/8 & 1/2 NPTF
-
5599/2-3: 1/2 & 3/4 NPTF
-
15407-2, 18mm: 1/8 threaded, 1/4 push in, 6mm, 8mm
-
15407-2, 26mm: 1/4, 3/8, 8mm, 10mm
-
-
5 ported, 4-way, 2 and 3 position, spool & sleeve
-
Flow Capacity:
-
5599/2-1: 60.1 SCFM @ 80 PSIG / 1280 NI/m @ 6 bar
-
5599/2-2: 134 SCFM @ 80 PSIG / 2857 NI/m @ 6 bar
-
5599/2-3: 245 SCFM @ 80 PSIG / 5222 NI/m @ 6 bar
-
-
Operating Pressure Range: 28" Hg. Vacuum to 150 PSIG / Vacuum to 10 bar
-
Pilot Pressure Range: 15 to 125 PSIG / 1 to 8.6 bar
-
Temperature Range (Ambient): -10°F to +115°F / -23°C to +46°C
-
Features:
-
Fieldbus Electronics and I/O Capable
-
Direct solenoid and solenoid air pilot actuated
-
Conforms to ISO standards 5599/2 & 15407-2
-
AC or DC
-
NEMA 4/IP65
15407-2
5599/2